Sysmex XN-530
ConnectivityWise puts every XN-530 result in your EHR the moment the run finishes and tells your staff it's ready. One simple price per location covers it, along with every other instrument you run.
Tests the XN-530 runs
We'll confirm which of these your XN-530 is configured to run during implementation.
About the XN-530 Automated Hematology Analyzer
The XN-530 is the automated member of Sysmex's XN-L family, adding an automated sample loader, rack sampling and automatic rerun and reflex functionality to XN-Series technology in a compact footprint. It supports open and closed tube sampling, reports a six-part differential including immature granulocytes on every sample, and runs up to 60 samples per hour from a 25 µL whole blood aspiration. Measurement uses fluorescent flow cytometry for the differential, DC impedance with hydrodynamic focusing for RBC and platelets, and the cyanide-free SLS method for hemoglobin. It is compatible with standard tubes and BD Microtainer MAP tubes. Learn more about the instrument at the manufacturer's product page.
Why practices connect the XN-530
Rack loading means the instrument keeps working while your tech does something else, which is only worth it if the results do not then queue up waiting to be typed in. Sending each CBC to the chart as it completes keeps the batch moving all the way through to the record, with staff notified as results arrive.
Send XN-530 results to your EHR
Results from the XN-530 file into whichever EHR you run, matched to the order where you use one. We connect to any EHR or EMR that accepts results.
XN-530 connectivity questions
Can the XN-530 connect to my EHR?
Yes. ConnectivityWise interfaces the Sysmex XN-530 and posts its results into your EHR automatically, matched to the order where you use one, or filed directly where you don't. Nobody retypes a value.
Which EHRs can the XN-530 send results to?
Any EHR or EMR that accepts results, including Epic, athenahealth, eClinicalWorks, NextGen, Oracle Health, Greenway, and PointClickCare. Automatic result upload works with any order and results workflow.
Does quality control from the XN-530 get captured?
ConnectivityWise captures quality control results alongside patient results, so your CLIA records are complete when an inspector asks. What a given instrument reports varies by device, so we confirm exactly what your XN-530 emits during implementation.
What does it take to connect a XN-530?
The Data Sync Agent, one small install on any Windows computer in your organization, collects results from the instrument and syncs them securely to the ConnectivityWise cloud. A single installation covers every instrument and location you have, and a named human guides the setup and validation end to end.