Sysmex XN-10

Connect the XN-10 to your EHR, automatically.

ConnectivityWise puts every XN-10 result in your EHR the moment the run finishes and tells your staff it's ready. One simple price per location covers it, along with every other instrument you run.

Sysmex XN-10 point-of-care hematology instrument

Tests the XN-10 runs

WBC
RBC
HGB
HCT
MCV
MCH
MCHC
PLT (PLT-I, PLT-F)
NEUT#, NEUT%
IG#, IG%
LYMPH#, LYMPH%
MONO#, MONO%
EO#, EO%
BASO#, BASO%
NRBC#, NRBC%
RDW-SD
RDW-CV
MPV
RET#, RET%
IRF
RET-He
IPF#, IPF%

We'll confirm which of these your XN-10 is configured to run during implementation.

About the XN-10 Automated Hematology Analyzer

The XN-10 is the analytical module at the core of the Sysmex XN-Series, and the CBC module supplied as standard in the XN-1000 configuration. It combines fluorescent flow cytometry using a semiconductor laser, DC impedance with hydrodynamic focusing, and the cyanide-free SLS method for hemoglobin, processing up to 100 CBC+DIFF samples per hour per module from an 88 µL whole blood aspiration. Alongside the standard CBC and differential it reports advanced clinical parameters, including immature granulocytes with every differential, nucleated RBC with every CBC, reticulocyte hemoglobin (RET-He) and immature platelet fraction. An optional Blood Bank mode lets the same instrument switch from whole blood CBC to a blood product cell counter, reporting RBC, HGB, HCT and PLT on RBC and platelet components. Learn more about the instrument at the manufacturer's product page.

Why practices connect the XN-10

A CBC with differential is one of the highest-volume orders in the building, and every one of those results has to land in the chart. Sending them straight from the instrument means nobody is transcribing counts off a printout or a worklist, and the result reaches the record as soon as the run finishes. Staff are notified when it arrives, so an abnormal count is not sitting unseen on the instrument screen.

Send XN-10 results to your EHR

Results from the XN-10 file into whichever EHR you run, matched to the order where you use one. We connect to any EHR or EMR that accepts results.

XN-10 connectivity questions

Can the XN-10 connect to my EHR?

Yes. ConnectivityWise interfaces the Sysmex XN-10 and posts its results into your EHR automatically, matched to the order where you use one, or filed directly where you don't. Nobody retypes a value.

Which EHRs can the XN-10 send results to?

Any EHR or EMR that accepts results, including Epic, athenahealth, eClinicalWorks, NextGen, Oracle Health, Greenway, and PointClickCare. Automatic result upload works with any order and results workflow.

Does quality control from the XN-10 get captured?

ConnectivityWise captures quality control results alongside patient results, so your CLIA records are complete when an inspector asks. What a given instrument reports varies by device, so we confirm exactly what your XN-10 emits during implementation.

What does it take to connect a XN-10?

The Data Sync Agent, one small install on any Windows computer in your organization, collects results from the instrument and syncs them securely to the ConnectivityWise cloud. A single installation covers every instrument and location you have, and a named human guides the setup and validation end to end.

See how the XN-10 connects to your EHR.
Fifteen minutes in the live product, mapped to your instruments and your EHR.
Book a demo