Beckman Coulter Coulter Ac•T diff

Connect the Coulter Ac•T diff to your EHR, automatically.

Also known as Coulter Ac·T diff, Coulter AcT diff.

ConnectivityWise puts every Coulter Ac•T diff result in your EHR the moment the run finishes and tells your staff it's ready. One simple price per location covers it, along with every other instrument you run.

Beckman Coulter Coulter Ac•T diff point-of-care hematology instrument

Tests the Coulter Ac•T diff runs

Complete Blood Count (CBC)
Histogram white blood cell differential

We'll confirm which of these your Coulter Ac•T diff is configured to run during implementation.

About the Coulter Ac•T diff Hematology Analyzer

The Coulter Ac•T diff is a compact bench-top hematology instrument from Beckman Coulter, built around the company's histogram differential technology. Beckman Coulter positions it for physician office labs and smaller laboratories running up to 50 CBCs a day, and publishes results in less than 60 seconds from venous or capillary whole blood. It uses one-step sample processing through a touch-screen interface, with an automated probe wipe and no routine maintenance requirement. Beckman Coulter still supports the instrument but notes it may not be available in every country, and directs new buyers to the DxH 500 Series. Learn more about the instrument at the manufacturer's product page.

Why practices connect the Coulter Ac•T diff

Results in under a minute lose their advantage if someone still has to key them into the chart afterwards. ConnectivityWise moves the count into the patient's record automatically when the run finishes and notifies your staff, so the clinician sees it without a printout in between. It also means a legacy instrument keeps earning its place instead of forcing a replacement.

Send Coulter Ac•T diff results to your EHR

Results from the Coulter Ac•T diff file into whichever EHR you run, matched to the order where you use one. We connect to any EHR or EMR that accepts results.

Coulter Ac•T diff connectivity questions

Can the Coulter Ac•T diff connect to my EHR?

Yes. ConnectivityWise interfaces the Beckman Coulter Coulter Ac•T diff and posts its results into your EHR automatically, matched to the order where you use one, or filed directly where you don't. Nobody retypes a value.

Which EHRs can the Coulter Ac•T diff send results to?

Any EHR or EMR that accepts results, including Epic, athenahealth, eClinicalWorks, NextGen, Oracle Health, Greenway, and PointClickCare. Automatic result upload works with any order and results workflow.

Does quality control from the Coulter Ac•T diff get captured?

ConnectivityWise captures quality control results alongside patient results, so your CLIA records are complete when an inspector asks. What a given instrument reports varies by device, so we confirm exactly what your Coulter Ac•T diff emits during implementation.

What does it take to connect a Coulter Ac•T diff?

The Data Sync Agent, one small install on any Windows computer in your organization, collects results from the instrument and syncs them securely to the ConnectivityWise cloud. A single installation covers every instrument and location you have, and a named human guides the setup and validation end to end.

See how the Coulter Ac•T diff connects to your EHR.
Fifteen minutes in the live product, mapped to your instruments and your EHR.
Book a demo